Seco-Larm E-941SA-600DPSQ 600lb Electromagnetic Lock w/ LED
In stock
SKU
secolarm:e941sa600dpsq
$147.00
- UL 294 Listed (Access Control)
- Built-in bond sensor with 3A-amp dry relay output for monitoring door lock status
- Built-in dual-color status LED shows lock status
- Built-in door position sensor shows open/closed status (1/2” gap)
- Armature plate holder for door position sensor
- Dual voltage: 12/24VDC selectable
- Anodized aluminum housing (US28)
- No residual magnetism
- MOV surge protection
- Detachable faceplate
- Adjustable mounting bracket
- Complete mounting hardware for typical installations
- “L” bracket (E-941S-600/LQ), “Z” brackets (E-941S-600/ZQ) available for easy mounting
- UL 294 Listed (Access Control)
- Built-in bond sensor with 3A-amp dry relay output for monitoring door lock status
- Built-in dual-color status LED shows lock status
- Built-in door position sensor shows open/closed status (1/2” gap)
- Armature plate holder for door position sensor
- Dual voltage: 12/24VDC selectable
- Anodized aluminum housing (US28)
- No residual magnetism
- MOV surge protection
- Detachable faceplate
- Adjustable mounting bracket
- Complete mounting hardware for typical installations
- “L” bracket (E-941S-600/LQ), “Z” brackets (E-941S-600/ZQ) available for easy mounting
Endurance | Level IV |
Destructive attack | Level 1 |
Line security | Level 1 |
Standby power | Level 1 |
Holding Force | 600-lb |
UL Listed | UL 294, ULC S104, UL 10B, UL 10C |
Operating Voltage | 12/24 VDC |
Current Draw | 12VDC: 500mA 24VDC: 250mA |
Housing material | Reed switch, 0.2A@12VDC |
Operating Temperature | 32°~120°F (0°~49°C) |
Electromagnet Dimensions | 9-13/16"x1-11/16"1" (250x43x25 mm) |
Armature Dimensions | 7-1/4"x1-1/2"x1/2"(185x38x12 mm) |
Bond Sensor | SPDT relay, 3A@12VDC |
DOORS LOCK, BUT CAN EASILY BE FORCED OPEN?
- Make sure the electromagnet and armature plates are properly aligned.
- Make sure the contact surfaces of the electromagnet and armature plates are clean and free from rust.
- Check the power leads with a meter, and make sure 12VDC or 24VDC is present.
- Make sure the rubber washer is installed and free from damage.
DELAY IN DOOR RELEASING?
- The electromagnet is fitted with a metal oxide varistor to prevent interference, so do not install a second diode.
- Ensure that the control device is connected between the power source and the positive terminal of the lock