The SECO-LARM EAP-5D1Q and EAP-5D5Q power supplies are specifically designed for an access control system's electronic locks and accessories. These power supplies centralize the power sources of access control equipment. They include two supervision relays that can be used to integrate with other systems such as an alarm control panel. Robust fault response and indication also includes gradual shutdown on output overload as well as immediate shutdown on output short, signalled by flashing red LED and with auto-recovery once output short or overload is removed.
Features
AC power failure supervision relay
Battery failure supervision relay
Selectable 2.2KΩ End-of-Line (EOL) resistor for AC failure and battery failure supervision relays via DIP switch
Selectable delay timer (5 sec., 5 min., 5 hours) for AC failure supervision relay via DIP switch
Board designed with overload and short-circuit protection, including automatic shutdown and LED overload indicator
Over-current fuse-protected AC input
Built-in back-up battery charger (back-up battery is optional)
Automatically switch to back-up battery if AC fails
Individual AC input and DC output LEDstatus indicators
Power
Field selectable for 12VDC or 24VDC output
Operating voltage input 110~240 VAC
Adjustable voltage range (11~15 VDC, 23~28 VDC) to compensate for voltage drop
Supply current: 5 Amps @ 12VDC,2.5 Amps @ 24VDC
AC input fuse rating 3.15 Amps (glass fuse)
Enclosure
Heavy-duty steel case to protect thepower connections
Removable steel cover for easy access
Ventilation holes to prevent heat build-up
Enclosure has enough room for two7AH batteries
6-foot power cord and battery leads included
Dimensions: 12-3/16" x 12-7/16" x 3-9/16"
Knock-out on the cover for optional cam lock
SpecificationsRelated Products
Input Voltage 110~240VAC
Output Voltage 12 or 24VDC selectable via DIP switch
Adjustable Output Voltage Range 11~15 @ 12VDC setting, via VR switch, 23~28 @ 24VDC setting, via VR switch
Number of Outputs 1
Total Supply Current 5A@12VDC / 2.5A@24VDC
Input Fuse Rating 3.15A ( glass fuse, AC)
LED Status Indicator AC input ( Green ), DC Output ( Red )
End-of-Line Resistor (EOL) Selectable ON ( 2.2KΩ) or OFF via DIP switch
AC-Fail Relay Delay Timer Selectable @ 5sec, 5min or 5hr via DIP switch
Supervision Relays Contact Rating: 3A@24VDC Dry Relay Output